一、Who shall install Continuous Water Monitoring System (CWMs) and dates of CWMs’data disclosure

Monitoring data of CWMs can be queried from January 1, 2015:
(一) Approved and licensed waste (sewage) water discharge of more than 2,000 cubic meters per day for the Industrial Parks’Sewerage System.
(二) Industries other than power plants that discharge more than 15,000 cubic meters of waste water (sewage) per day are approved.
(三) Power plants with air pollution prevention and control facilities whose emissions have not come into contact with cooling water or seawater exhaust smoke desulfurization .
From January 1, 2017, new query monitoring data objects can be added:
(一) Approved industries with a waste (sewage) discharge volume of more than 5,000 cubic meters per day but less than 15,000 cubic meters.
(二) Approval of the Industrial Parks’Sewerage System with a waste (sewage) discharge of more than 1,500 cubic meters per day but less than 2,000 cubic meters.
From July 1, 2017 onwards, new monitoring data objects can be queried: approved industries whose waste (sewage) discharge exceeds 1,500 cubic meters per day but less than 5,000 cubic meters.
Starting from January 1, 2019, new monitoring data objects can be added: those who discharge waste (sewage) water to surface water bodies from public sewage sewer systems with approved waste (sewage) discharge volumes of more than 5,000 cubic meters per day.
Starting from July 1, 2019, new monitoring data objects can be added: those who discharge waste (sewage) water to surface water bodies from public sewage sewer systems with approved waste (sewage) discharge volumes of more than 1,500 cubic meters per day.

二、Monitoring items

1.Industrial Parks’Sewerage System
Continuous Water Monitoring System should be set Industrial Parks’Sewerage System
Water volume monitoring location inlet , outfall
Water quality monitoring location outfall
Water Quality Monitoring items 1.Water temperature
2.Hydrogen ion concentration index
3.Electrical conductivity
4.Chemical oxygen demand
5.Suspended solids
6.Other water quality items designated by the competent authority
CCTV location outfall
Rainwater discharge outfall designated by the competent authority
connection transmission facility It should maintain a connection with the municipal and county (city) competent authorities for transmission
2.Industries other than power plants
Continuous Water Monitoring System should be set Industries other than power plants
≧ 5,000 cubic meters 1,500~5,000 cubic meters
Water volume monitoring location outfall
Water quality monitoring location outfall
Water Quality Monitoring items 1.Water temperature
2.Hydrogen ion concentration index
3.Electrical conductivity
4.Chemical oxygen demand
5.Suspended solids
6.Other water quality items designated by the competent authority
1.Water temperature
2.Hydrogen ion concentration index
3.Electrical conductivity
CCTV location outfall No need to set
connection transmission facility It should maintain a connection with the municipal and county (city) competent authorities for transmission No connection is required, but it is necessary to set the water volume and water quality to automatically display the bulletin board
3.Power plants
Automatic monitoring (viewing) connection facility objects should be set for seawater exhaust smoke desulfurization in power plants Power plants with emissions not exposed to cooling water
Water monitoring location outfall
Water quality monitoring location outfall
Water Quality Monitoring Project Hydrogen ion concentration index water temperature
Video surveillance location Wastewater discharge port for seawater flue gas desulfurization No need to set
connection transmission facility It should maintain a connection with the municipal and county (city) competent authorities for transmission It should maintain a connection with the municipal and county (city) competent authorities for transmission
4.Major violations
Continuous Water Monitoring System should be set Major Violators Note
Water volume monitoring location All water sources, discharge outfalls and discharge outfalls included in the sewage sewer system within the scope of operation
Water quality monitoring location The inlet / outlet/discharge outfall /discharge outfall of each water treatment facility unit into the sewage sewer system
Water Quality Monitoring Project 1.Water temperature
2.Hydrogen ion concentration index
3.Electrical conductivity
4.Other water quality items designated by the competent authority
CCTV location Each water treatment unit and discharge outfall
connection transmission facility It should maintain a connection with the municipal and county (city) competent authorities for transmission
Note : Major violators are subject to Article 56 of the Water Pollution Control Measures and Test Reporting Management Regulations.
5.Those who discharge waste (sewage) water to surface water bodies from the public sewage sewer system
Continuous Water Monitoring System should be set public sewage sewer system
≧ 5,000 cubic meters 1,500~5,000 cubic meters
Water volume monitoring location outfall
Water volume monitoring location outfall
Water Quality Monitoring Project 1.Chemical oxygen demand
2.Suspended solids
3.Other water quality items designated by the competent authority
CCTV location outfall
connection transmission facility It should maintain a connection with the municipal and county (city) competent authorities for transmission